BTG 28 P 60Hz - Burners Baltur

BTG 28 P 60Hz

Code 17155410

Two-stage gas burners.

  • Two-stage.
Technical data
Fuel
Natural Gas
Operation
Two-stage
Minimum Thermal Power (kW) to ErP
80
Maximum Thermal Power (kW) to ErP
280
Min flow rate (Sm³/H)
8.5
Max flow rate (Sm³/H)
29.6
Electric power supply type
AC
No. of Phases
1N
Power Supply Voltage (V)
220
Power Supply Frequency (Hz)
60
Fan Motor Power (kW)
0.2
Weight without packaging (kg)
17
Weight with packaging (kg)
18
Width (mm)
780
Depth (mm)
370
Height (mm)
410
Technical Descriptions
Gas burner compliant with European standard EN676. Two-stage operation.
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 2.
Regulating combustion air and blast-pipe.
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.
Fully closing air damper on shutdown to avoid loss of heat through the chimney.
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
CE version gas train is complete with operation and safety valve with electromagnetic drive, minimum pressure switch, pressure regulator and gas filter.
Possibility to choose gas train with valve tightness control.
Fail proof connectors for burner/gas train connection
Gas train exit: high.
Sound-proof plastic protective cover.
Flame detection by ionisation electrode with connector for micro amp meter.
7-pole socket for burner electric and thermostatic supply.
4-pole socket for second stage control.
Electric protection rating:
Documents
Public documents
Type summary
Revision
Publish Date
Languages
Technical Sheet
1.0
01/07/2021
Use and maintenance manual
201211
 
Reserved documents
Operating range

This product is part of the range BTG P

Discover the entire series
Login
Cookies help us deliver our services. Using these services, you agree to the use of cookies on our part. Info